I2C Modbus RTU Slave Chip – IS4310
Price range: 1,95 € through 3,00 €
Select options
This product has multiple variants. The options may be chosen on the product page
ā 500 Holding RegistersĀ for user data
ā
Available Function Codes:
– 0x03 Read Holding Registers
– 0x06 Write Single Register
– 0x10 Write Multiple Registers
ā
Default Modbus Settings:
– Modbus Slave ID: 1
– Modbus Baud Rate: 19200 bps
– Modbus Parity: Even
– Modbus Stop Bits: 1
ā
I2C Characteristics:
– I2C Slave Address:Ā 0x11 (fixed)
– I2C Speed: 100 kHz, 400 kHz, 1 MHz
– I2C Voltage: 3.3 V (5 V tolerant)
Out of stock
TheĀ IS4310-ISO485M6Ā is a Modbus ISOLATED RS485 module that integrates aĀ Modbus RTU stack chipĀ (IS4310), anĀ RS485 transceiverĀ andĀ two daisy-chained RJ45 connectors. The module isolates the RS485 bus from the rest of the electronics, ensuring a robust solution for harsh electrical environments or long RS485 cable runs with significant ground potential differences.
ByĀ integrating this moduleĀ into your project, you instantly get aĀ working Modbus RS485 interfaceĀ ā just read from or write to theĀ IS4310’s I2C memory registers, whichĀ directly map to the Modbus Holding Registers.
This solutionĀ minimizes the design effortĀ required to integrate a Modbus RTU Slave with an RS485 physical layer.
Optionally, you canĀ integrateĀ theĀ IS4310Ā chipĀ in your own designĀ to minimize costs and customize the connector. Example schematics can be found in the IS4310 datasheet.
TheĀ IS4310Ā is a chip that integrates aĀ Modbus RTU SlaveĀ stack. It features an internal memory ofĀ 500 Holding Registers, accessible by both aĀ microcontroller (via I2C)Ā and aĀ Modbus Master deviceĀ (e.g., PLC, computer, etc.).
You can use the IS4310 in three modes:
Just read/write the registers you need āĀ no protocol stack required.
The goal of the IS4310 is to eliminate the engineering effort typically required to implement and validate Modbus RTU communication. It offers aĀ reliable, ready-to-use solutionĀ that helps reduce development time and speed up yourĀ time-to-market (TTM).
The module provides two interfaces:
The internal memory is composed ofĀ 504 registers:
The 500 Holding Registers are the key:
Whatever you write to the 500 Holding Registers via I2C will be accessible by the RS485 master device ā and vice versa: whatever the RS485 master device writes to the 500 Holding Registers will be accessible by your microcontroller via I2C.
Default Modbus Settings:
119200 bpsModbus Parity:Ā Even1Default I2C Settings:
0x11Ā (fixed)100 kHzĀ (pin to GND),Ā 400 kHzĀ (pin to 3.3V/2),Ā 1 MHzĀ (pin to 3.3V)IS4310-ISO485M6 User Manual